AIC-1708

The AIC-1708 is a multipurpose Industrial Computer with inbuilt M.2 SSD storage for data. It is based on a quad-core  ARM Cortex-A53 64-bit processor. The computer is richly equipped with wireless interfaces. With robust features, customizable options, and com...

AG-702

The AG-702 is multipurpose Industrial IoT Gateway based on OpenWRT system. Open WRT support more than 6000 ready applications in our repository. AG-702 has opto-isolated RS485 and RS232, two digital inputs and one relay output. Support Modbus RTU and Modbus TC...

AG-207

Industrial IoT Gateway AG-207 powered by the OpenWRT system. With OpenWRT, you gain access to an expansive repository of over 6000 ready-to-use applications, along with the freedom to integrate your own custom solutions. This cutting-edge gateway, AG-207 featu...

ADI-524

The ADI-524 is 4 channel 4-20mA analog to RS485 converter using standard Modbus-RTU protocol. It has dedicated RS485 port for output which need power supply to lit up device or It can work over single USB port having power supply and RS485 output in it. Pleas...

AG-1629

Programmable industrial IoT Gateway working on Linux systems. It provides the ability to install custom scripts and use ready-made scripts. Under the control of the NodeRED it gives unlimited possibilities for easy creation of gateway operation logic. It also ...

AG-201

AG-201 stands as the basic Modbus RTU gateway for users seeking LTE connectivity for their custom applications. This gateway features both RS485 and LTE/GPRS communication capabilities, complete with SMS support. AG-201 ensures bidirectional connectivity, enab...

Thermolog

Thermolog V3-T is temperature logger dedicated for applications where visual temperature control is needed and it is also necessary to save log to non-volatile memory. Thermolog V3-T has the ability to set the range of the permissible temperature. An alarm is ...

ALWG-1638

Atreyo LoRaWAN® gateway is powered with an ARM Cortex-A7 processor with ease of outdoor installation and IP67-rated environment-resistant aluminum enclosure to support your smart city, smart industry, professional LoraWAN® network applications, and industrial ...

AG-831

The AG-831 is a Gateway dedicated to work witch central controlling and monitoring systems. It support two-way communication with server trough LTE/GSM or Ethernet. It has inbuilt timer with 10 ON/OFF schedule within 24h, auto configurable sunrise/sunset timer...

AM-201

AM-201 is LTE modem for use in industrial environment. It communicate to host by USB, RS485 and RS23. It can be used with operating systems such as Windows and Linux. For use in IoT systems, industrial control systems, control panels and distribution systems, ...

AMB-4I-4O

The AMB-4I-4O is an input/output interface module to Modbus RTU over RS485. It has 12 isolated digital input with high voltage range up to 30VDC and 4 relay output with 5A 230V range and NO contacts. The power supply range is 8 to 36V and accept DC or AC volta...

AMB-12I-4O Expander

The AMB-12I-4O is an input/output interface module to Modbus RTU over RS485. It has 12 isolated digital input with high voltage range up to 30VDC and 4 relay output with 5A 230V range and NO contacts. The power supply range is 8 to 36V and accept DC or AC volt...

AG-801

The AG-801 Gateway can be controlled via TCP commands from server. All Modbus queries can be controlled from server. In addition Gateway has support of JSON string format but limited to Modbus interface. JSON communication is one way communication dedicated mo...

AG-1621

The AG-1621 is a Quad-core, highly effective ARM-based compact-size multipurpose industrial computer with IoT gateway functionality. It is designed for edge computing. It supports a variety of Linux distributions, including Rasberry Pi OS, Debian, OpenWRT, and...

AMB-8I-4O Expander

The AMB-8I-4O input/output expander with Modbus RTU and IEC-60870-5-101 protocol support (under development). It has 8 isolated digital inputs with voltage range up to 30VDC and 4 relay output with 5A 230V range and NO contacts. The power supply range is 8 to ...

Configuration manual

AIC-1708

The computer comes with Linux preloaded and configured.

General information

AIC-1708

Model Selection Atreyo roduces different versions of the AIC-1708. Below is a table of model selection. If there is no interface listed in the table, it means that it slips in all versions.      Model Variant Internal storage RAM SSD Cellular Netwo...

Configuration Manual

AG-702

Please read carefully before starting. Also read the product safety information. First start After unpacking, the gateway is ready to use, but requires configuration to adapt to the required functions.  Power supply First, connect the power supply acco...

Safety information

AG-702

Operating environment The device is designed to be installed in clean, dust-free and insect-free places Operating temperature: -25 ~ 65°C (-13 ~ 149°F). Humidity range is 10% to 95% (non-condensing). Use the device in a dry environment. Away from heat so...

General information

AG-702

Download technical specification Technical Specification Model selection Different Gateway models are available depending on the periphery availability and type. Model Cellular Network GNSS Internal memory AG-702 GPRS 3G LTR ...

Firmware update

AG-702

The system can be updated via the built-in website. We can update OpenWRT firmware both when the system is running and when it's in U-Boot mode. In cases we need to have a firmware file with a new system compatible with this gateway model. Uploading the incorr...

General information

AG-207

Download technical specification Technical Specification Model selection Different Gateway models are available depending on the periphery availability and type. Model Cellular Network GNSS Internal memory AG-207 GPRS 3G LTR ...

Safety information

AG-207

Operating environment The device is designed to be installed in clean, dust-free and insect-free places Operating temperature: -25 ~ 65°C (-13 ~ 149°F). Humidity range is 10% to 95% (non-condensing). Use the device in a dry environment. Away from heat so...

Configuration Manual

AG-207

Please read carefully before starting. Also read the product safety information.This guide is updated regularly. First start After unpacking, the gateway is ready to use, but requires configuration to adapt to the required functions.  Power supply Firs...

Applications

AG-207

The gateway has the ability to install many ready-made applications.  For this purpose, the gateway must be connected to the Internet. You need to go to System > Software. First click Update Lists... After waiting a while, the "Executing package manager" wi...

General information

ADI-524

Download technical specification Technical Specification ADI-524 has 4 opto-isolated analog inputs and RS485/USB output. It is also featured with isolated 24V power output to feed 4-20mA sensors/devices. For baud rate and Modbus address configura...

Configuration Manual

ADI-524

Please read carefully before starting. Also read the product safety information. Wiring and connection The ADI-524 can be powered from a DC power supply in the range of 8-36V. Also, it can be powered from the USB port of a computer or IoT gateway. Both power...

Protocol Description

ADI-524

Overview The MODBUS protocol is a widely used communication standard in industrial automation, facilitating master-slave data exchange. It is known for its simplicity and flexibility, making it suitable for a range of applications in connecting intelligent de...

General information

AG-201

Download technical specification Technical Specification Hardware The Gateway is made on one PCB, which is fitted to the aluminum housing. The housing is made of a thick, strong aluminum profile with two end plates also made from aluminum. The s...

Configuration Manual

AG-201

After unpacking, the gateway is ready to use, but requires configuration to adapt to the required functions. Power supply The device can be powered by connecting a power source to the terminal block:   Loosen or remove the screws on the terminal block. C...

Safety information

AG-201

Operating environment The device is designed to be installed in clean, dust-free and insect-free places Operating temperature: -25 ~ 65°C (-13 ~ 149°F). Humidity range is 10% to 95% (non-condensing). Use the device in a dry environment. Away from heat so...

Safety information

AG-1629

Operating environment The device is designed to be installed in clean, dust-free and insect-free places Operating temperature: -25 ~ 65°C (-13 ~ 149°F). Humidity range is 10% to 95% (non-condensing). Use the device in a dry environment. Away from heat so...

Safety information

ADI-524

Operating environment The device is designed to be installed in clean, dust-free and insect-free places Operating temperature: -25 ~ 65°C (-13 ~ 149°F). Humidity range is 10% to 95% (non-condensing). Use the device in a dry environment. Away from heat so...

Safety information

AIC-1708

Operating environment The device is designed to be installed in clean, dust-free and insect-free places Operating temperature: -25 ~ 65°C (-13 ~ 149°F). Humidity range is 10% to 95% (non-condensing). Use the device in a dry environment. Away from heat so...

Overview

Thermolog