Firmware update
The system can be updated via the built-in website. We can update OpenWRT firmware both when the system is running and when it's in U-Boot mode. In cases we need to have a firmware file with a new system compatible with this gateway model. Uploading the incorrect image may cause the device to malfunction.
When OpenWRT is running
Go to System > Backup / Flash Firmware. At the bottom of the page is an option to Flash new firmware image. Select the correct system image and click Flash Image.
This is followed by a firmware file selection window.
Select the correct file and click upload.
The file will be loaded into the gateway and verified. If it is verified correctly it will go to the window where the option "Keep settings and retain the current configuration" will be checked. If you do not care about keeping the configuration, it is better to uncheck this option.
Then you have to wait a few minutes for the system to load and update.
Do not turn off the gateway while the system is being updated. This will damage the system.
By U-Boot mode
This method of uploading firmware should only be used when the system is not working and the firmware cannot be uploaded in the normal way. To enter U-Boot mode press RESET switch for 4 seconds when switching on the power supply. The Gateway should start on U-Boot mode. In U-Boot mode, the white STAT LED glows continuously. To access internal website go to IP 192.168.10.50 and load firmware from proper firmware file provided by Atreyo.
Uploading incompatible firmware not provided by Atreyo will void the warranty.
Then you have to wait a few minutes for the system to load and update.
Do not turn off the gateway while the system is being updated. This will damage the system.
Firmware list
The Gateway works on the OpenWRT operating system. The operating system is specially prepared and compiled for hardware. So when it is booted up, it is ready for use. In addition to the pre-installed application, we provide our own repository of free apps compiled for this Gateway. We update the system regularly to keep the latest version. You can check the latest releases here.
V1.01.05
With built-in Modbus Master. IPV6 support added.
AG-702-LT-EU version
Firmware Version | File name | Kernel |
OpenWRT |
Date |
V1.01.05a | File download | 5.15.71 | 08.01.2025 |
AG-702-LT-GL version
Firmware Version | File download |
Kernet |
OpenWRT |
Date |
V1.01.05a | 5.15.71 | 08.01.2025 |