Safety information

AIC-1708

Operating environment The device is designed to be installed in clean, dust-free and insect-free places Operating temperature: -25 ~ 65°C (-13 ~ 149°F). Humidity range is 10% to 95% (non-condensing). Use the device in a dry environment. Away from heat so...

General information

Thermolog

Download technical specification Thermolog V3-T Technical Specification Download technical specification Thermolog V3-TH Technical Specification Connection The thermologist on the right has a set of sockets for power and sensor connections...

Configuration manual

Thermolog

Thermolog can be configured in two ways. One by using the buttons and the menu that will appear on the display, or by using Modbus and commands from the dedicated Thermometer PC application or any other software with Modbus function. The offered device has def...

Protocol Description

Thermolog

Thermolog sends data using the Modbus proto protocol. Below is a description of the protocol. Readable registers 0x04 – 30000 Address Hex Address Parameter Organization Example Value Accuracy Example 30000 0x00 Temperature int32 ...

Safety information

Thermolog

Operating environment The device is designed to be installed in clean, dust-free and insect-free places Operating temperature: -25 ~ 65°C (-13 ~ 149°F). Humidity range is 10% to 95% (non-condensing). Use the device in a dry environment. Away from heat so...

General Information

ALWG-1638

Download technical specification Technical Specification Model selection Different LoRaWAN Gateway models are available depending on frequency band/region and on the periphery availability and it's type. Model Lora frequency / Country C...

Safety information

ALWG-1638

Operating environment The device is designed to be installed in clean, dust-free and insect-free places Operating temperature: -25 ~ 65°C (-13 ~ 149°F). Humidity range is 10% to 95% (non-condensing). Use the device in a dry environment. Away from heat so...

Configuration Manual

ALWG-1638

First start After unpacking, the gateway is in ready-to-use condition but requires a few configurations to adapt to the required functions. Power Supply Connect the gateway to the power supply as referenced in the below diagram, and use the standard input...

Safety information

AG-831

Operating environment The device is designed to be installed in clean, dust-free and insect-free places Operating temperature: -25 ~ 65°C (-13 ~ 149°F). Humidity range is 10% to 95% (non-condensing). Use the device in a dry environment. Away from heat so...

General Information

AG-831

Download technical specification Technical Specification The AG-831 is a Gateway dedicated to work witch central controlling and monitoring systems. It support two-way communication with server trough LTE/GSM or Ethernet. It has inbuilt timer w...

Node-RED

ALWG-1638

NodRED functionality is pre-installed and it has been hosted on 1880 port. To access NodeRED use icon in Application section or open browser and hit "<gateway_IP>:1880"  New tab will open and and it might pop-up for user/pass if you are using it either first...

Firmware releases

ALWG-1638

The Gateway works on the OpenWRT operating system. The operating system is specially prepared and compiled for hardware. So when it is booted up, it is ready for use. In addition to the pre-installed application, we provide our own repository of free apps comp...

Use cases/ Examples

ALWG-1638

Application City and Industry LoraWAN applications Smart Street Light, Energy meters, water meters, and other  meter applications

Chirpstack LNS

ALWG-1638

Once the Chirpstack LNS has been configured in gateway side, few things to be done in Chirpstack console. i.e. to add Gateway, End devices, Application etc. to Add gateway in chirpstack LNS open chirpstack LNS by clicking the icon in Application. Login pop...

Modbus Master

AG-702

Modbus Master is an application that allows full operation of devices connected to the gateway over Modbus RTU and Modbus TCP/IP. Also, the application allows sending data to the server via MQTT, TCP/IP JSON and saving to storage. Configuration of Modbus Ma...

Configuration manual

AG-831

Connect the correct power supply. You can choose the right power supply in the power supply section.Then connect the LAN cable to the gateway to the router. It is important that the IP address is in the range of 192.168.10.xxx. To enter internal website of Ga...

SMS functions

AG-831

Firmware / OS list

AIC-1708

Firmware list Information about future releases of Ubuntu for this computer. OS Version File name Kernel Ubuntu Date